More heat-pump settings

Set the bivalence temperature, heating-rod power and storage sizes for the heat pump on an offer.

Once a heat pump is on the offer, the Additional settings card in the Heating section carries the per-offer settings that shape the simulation. These are separate from the catalog component. They live on this offer, and you adjust them per project.

Residential only. Heat pumps are a residential product, so this flow applies to residential projects.

Set the bivalence temperature

The bivalence temperature is the outside temperature below which a second heat source helps the heat pump. That source is the heating rods in the storage tanks, plus the customer's existing heating when the offer uses it as a second heating system. Otherwise the existing heating is only the baseline for the cost comparison. The heat pump keeps running first below this point.

  1. Open the offer on the Planning view.
  2. Open the Heating section, then the Additional settings card.
  3. Find the Bivalence temperature field. It shows −5 as a placeholder. If you leave it empty, the simulation uses −5°C.
  4. Leave the value at its default unless you have a reason to change it. Sizing the heat pump correctly has a much larger effect on the result.
  5. Lower it (for example −10°C) to limit the help from the tank rods and the existing heating to the coldest days.
  6. Raise it (for example −2°C) to let the tank rods and the existing heating help on more days.

Note

A heating rod turns 1 kWh of electricity into 1 kWh of heat, while a heat pump delivers several kWh of heat per kWh. The more of the demand the rods cover, the higher the operating cost. Check the operating cost after you change this.

The −5°C default is the same in every country. The heat-pump sizing calculator uses its own bivalence point of −6°C as a calculation input only. It doesn't change this field, so set it here. See Dimensioning table for the heat-pump sizing surface.

Set the heating-rod power and storage sizes

Set these in the same card so they match the parts you're installing.

  1. Enter the heating-rod power of the rod you're installing. The field is hidden when the heat pump has an integrated heating rod, because that rod is already on the component.
  2. Enter the storage sizes. The heating-storage size is hidden when the heat pump has integrated heating storage.

Run the simulation

  1. Click Calculate Costs / Simulate to run the simulation.
  2. Check how the operating cost changes. The annual consumption and operating cost flow into the offer PDF and the customer-facing figures.

Things to know

  • The heat pump runs first below the bivalence point. The simulation runs in 15-minute steps. Below the bivalence point, the tank rods, and the existing heating when the offer uses it, cover only what the heat pump leaves over. For warm water and heating storage, the tank's own rod runs before the rod in the heat-pump body. For space heating, the heat-pump rod doesn't follow the bivalence point. It switches on once uncovered demand has risen for five consecutive steps (a little over an hour) and switches off as soon as demand is covered.
  • Record the existing heating first. The planned heat pump is only simulated once the customer's existing heating, including its annual heating demand, is recorded. Without it, the heat pump is left out of the simulation and no error is shown.
  • Make sure a heating rod is recorded somewhere. The rod can be integrated in the heat pump, sit in a storage tank, or be a standalone rod on the offer. If none of these carries a rod, the simulation runs without one.
  • Enter each tank and rod once. The simulation adds integrated, standalone and existing storage and rods together. A tank or rod entered both on the heat pump and as a separate line item is counted twice.
  • The simulation needs a complete component. If the heat-pump component has an empty performance curve, the simulation reports that the heat pump can't be simulated and asks you to check whether the component's values are complete. On UK MCS components this usually means the SCOP value at 35°C or 55°C is missing. Fix the curve on the catalog component, then re-run.