Reonic

Add a heat pump to the offer

Attach a heat pump from your catalog to this offer, set its storage and heating-rod values, and run the simulation.

You choose the heat-pump model here. The dimensioning table suggests a kW figure from the building heat load, and you use that figure to pick a model of the right size.

Residential only. Heat pumps are a residential product, so this flow applies to residential projects.

Before you start

  • At least one heat pump exists in your components catalog.
  • Record the customer's existing heating. The planned heat pump is only simulated once the existing heating demand is recorded. Without it, the simulation runs without the heat pump. See Capture the existing heating and consumption.
  • Fill at least one method in the Heat load method section. The simulation runs on the method marked In use. See Run a simple heat-load simulation and Run a room-by-room heat-load calculation.
  • Optional: have a suggested kW figure from the Heat Pump Sizing table. In Germany and most markets, the table follows VDI guideline 4645 and reads the offer's heat load and the location's norm outside temperature. Projects in the UK or France get their own sizing views. A room-by-room heat-load calculation can supply that heat load. Outside Italy, the Simple simulation - Building basic data method carries only a heat load you enter manually. See Size the heat pump with the dimensioning table.

Attach the heat pump

  1. On the offer's Planning view, open the Heating section.
  2. Open the heat-pump selection. The Components dialog opens, pre-filtered to heat-pump types.
  3. Find the model that matches the customer's needs. Search by name, brand, or article number, and narrow the list with the component-type and business-domain filters.
  4. Compare the model's power with your suggested kW figure.
  5. Click Add on the row.
  6. Set the quantity with the quantity spinner.

Pro tip

Search by manufacturer and model number for an exact match.

The heat pump becomes a line item on the offer.

Run the simulation

  1. In the Additional settings card, set the Bivalence temperature. It determines when the second heating system starts. See More heat-pump settings.
  2. Set the storage sizes.
  3. Set the Heating-rod power. The field is hidden when the heat pump has an integrated rod.
  4. Click Calculate Costs to run the simulation.

The annual kWh, the annual performance factor (JAZ) and the operating cost flow into the offer PDF and the customer-facing figures.

Things to know

  • You size the heat pump from the building heat load. The catalog model you pick sets which product and which performance curve the simulation uses. The building's demand comes from the heat-load method marked In use. The Heat Pump Sizing table is a calculator: it suggests a kW figure, saves nothing and selects no component, so transfer its result by hand. Its −6 °C bivalency point is a sizing input only. The offer's bivalence temperature (default −5 °C) is set separately in Additional settings.
  • Integrated sub-components hide their fields. If the heat pump has an integrated heating rod, the Heating-rod power field is hidden. If it has integrated heating storage, the heating-storage size is hidden.
  • Record a heating rod somewhere. The simulation combines integrated, standalone and existing rods and storage. If none of them carries a rod, the simulation runs with no heating rod. Make sure the heat pump has an integrated rod or the package contains one.
  • The existing heating builds the comparison baseline. The existing heating sets the status-quo baseline for the profitability comparison and does not size the heat pump. The existing heating runs as the second heating system only when the variant is set to use the existing heating system. Otherwise, below the bivalence point, the heating rods cover the demand the heat pumps can't meet.
  • The electricity price has a large effect. Without a heat-pump tariff, the heat pump is priced with the offer's ordinary electricity tariff and its yearly increase.
  • You can add more than one heat pump. The simulation uses them in the order given until demand is met. A dedicated warm-water heat pump alone reheats the warm-water tank, and air-to-air heat pumps cascade separately. Bivalence applies to the whole variant, not to each component.
  • Keep PV and the heat pump in one variant when the customer should see the shared energy flows. If you tick existing PV in a heat-pump-only variant, the simulation assumes a PV system really exists.
  • If the simulation reports "Heat pump cannot be simulated. Please check whether the values in the component are complete.", the catalog component is missing data. Typically the 35 °C or 55 °C SCOP values are missing in UK MCS mode. Complete the component, then re-run.