Heat load indication

Decide whether building-envelope heat-load indication is the right sizing method — a real heat-pump sizing basis without running a full room-by-room scan.

Reonic offers three ways to establish a building's heat load, in increasing accuracy. Heat load indication is the middle one: it derives the heat load from the building envelope, using standard U-values by build year, giving a genuine sizing basis without per-room detail.

When to use it

  • Heat load indication (this method) — envelope-based, a real sizing basis, fast. Good for a committed offer where a full room-by-room scan isn't warranted yet.
  • Simple simulation — base data only; use it when an external heat-load figure already exists and you just need a simulation. The step-by-step for entering the envelope data lives on that page.
  • Room-by-room calculation — the full per-room method, and the only one that produces the hydraulic-balancing report and subsidy-grade documentation.

Pro tip

Sanity-check the indicated heat load against the customer's actual consumption — compare the result in kWh/m² against their old heating bill (see the existing heating you captured). A large gap usually means a wrong build year or insulation assumption.

Things to know

  • It's an indication, not a certified calculation. If the customer needs documentation for a subsidy application or you're swapping radiators, use the room-by-room method instead.
  • The envelope inputs can be refined per building element (custom U-values, added insulation) if the defaults don't match the building.
  • The step-by-step for entering the envelope data lives on the simple simulation page — the two simpler methods share the same entry point on the Building and heat load card.