Reonic

Heat load indication

Estimate a building's heat load from its envelope, using standard values by build year, so you can size a heat pump without a room-by-room calculation.

Heat load indication derives the heat load from the building envelope, using standard U-values by build year. It gives you a real sizing basis without per-room detail.

When to use it

Use heat load indication when you're sizing the heat pump for a committed offer, have the building's envelope data (build year, insulation), and a full room-by-room calculation isn't warranted yet.

Reonic offers two other ways to establish the heat load:

  • Simple simulation: use it when an external heat-load figure already exists and you only need a simulation.
  • Room-by-room calculation: the full per-room method, and the only one that produces the hydraulic-balancing report and subsidy-grade documentation.

Enter the envelope data

Heat load indication and the simple simulation share the same entry point, the Building and heat load card on the offer's Planning view. The steps for entering the envelope data are on Simple simulation. If the defaults don't match the building, refine the inputs per building element (custom U-values, added insulation).

Pro tip

Sanity-check the indicated heat load against the customer's actual consumption: compare the result in kWh/m² against their old heating bill (see Capture the existing heating and consumption). A large gap usually means a wrong build year or insulation assumption.

Things to know

  • It's an indication, not a certified calculation. If the customer needs documentation for a subsidy application or you're swapping radiators, use the room-by-room method instead.